Manual inspection machine is mainly used for inspecting short straight busbar, elbow busbar, terminal busbar and etc.. It’s composed of two parts: fixture positioning and main inspection instruments. Fixture positioning part is operated manually while inspection instruments will test the busbar and generate the report automatically.
The KD-JCX/M-6 Manual Inspection Line combines manual fixture positioning with automatic electrical testing. It is intended for short straight sections, elbow busbars, terminal busbars and other irregular geometries. The inspection instruments test the positioned busbar and generate a report automatically. Optional barcode and report printing support identification and record output without changing the manual positioning method. | Official Kiande Electric product image |
| Parameter | Specification |
|---|---|
| Published Model / Identifier | KD-JCX/M-6 |
| Busbar Height | 100mm – 650mm |
| Busbar Length | 500mm – 3000mm |
| Suitable Busbar Type | Irregular busbar |
| Position Type | Unilateral |
| Printing System | Bar code / Report printing (optional) |
| High Voltage Withstanding Test | 0 – 5 000 V |
| Insulation Test | 1 – 1 000 V |
| Grounding Test | 0 – 25 A |
| Power | 380~415VAC 50~60Hz 3kW |
| Equipment Dimension | L6200mm × W800mm × H800mm |
Irregular Section SupportThe published application includes short straight, elbow and terminal busbars. | Unilateral PositioningOperators position the workpiece using the unilateral fixture arrangement. | Withstand TestingThe high-voltage withstanding test range is 0–5000V. |
Insulation MeasurementThe insulation test range is 1–1000V. | Grounding TestThe listed grounding test current range is 0–25A. | Optional Printed RecordsBarcode printing and report printing are optional, as stated in the source table. |
FunctionsIrregular Section Support — The published application includes short straight, elbow and terminal busbars. Unilateral Positioning — Operators position the workpiece using the unilateral fixture arrangement. Withstand Testing — The high-voltage withstanding test range is 0–5000V. | Working Principle
|
Elbow Busbar InspectionElectrical testing of elbow sections requiring manual positioning. | Terminal Section TestingInspection of terminal busbars before the next production stage. | Short Straight SectionsTesting short straight busbars within the published length range. |
Provide elbow, terminal or short-section drawings for positioning review.
Define the required test voltage, current and procedure within the listed instrument ranges.
Specify whether barcode printing, report printing or both are required.
Recommended acceptance checks for manual inspection line:
Fixture CoverageConfirm secure positioning for a representative irregular section. | Instrument SettingsCheck the selected withstand, insulation and grounding settings against the test plan. | Report VerificationCompare the generated record and optional printout with the required inspection format. |
Dedicated Inspection EquipmentManual and automatic busbar inspection machines both appear in Kiande’s official range. | Relevant Busbar CoverageThis model is described specifically for short straight, elbow and terminal sections. | Testing and Data FocusThe company’s stated business includes intelligent production and data analysis for electrical manufacturing. |
Manual positioning handles geometry while the instruments perform testing automatically.
The three published electrical ranges help buyers compare the station with their inspection plan.
Kiande supplies assembly equipment as well as the inspection station used after assembly.
Other stations to compare within the inspection workflow: Manual Assembly Machine, Semi-Automatic Assembly Line, Automatic Busbar Assembly Line.
Busway quality inspection
Busbar trunking production
Electrical equipment manufacturing
Kiande’s official company profile lists manual inspection machines as part of its busbar production equipment range. Suzhou Kiande Electric Co.,Ltd. is headquartered in Suzhou, with a Zhenjiang manufacturing center and departments for design, production and service. | Factory scene published on Kiande’s official sister website |
Submit height, length and terminal or elbow drawings.
State the electrical test requirements and printing format.
Discuss inspection of a representative busduct section before fixing the equipment scope.
Kiande’s official website displays an invention patent document for busduct processing equipment. This is a company technology document. It does not establish CE conformity or current ISO certification for every product configuration. | Company-published invention patent document |
KD-JCX/M-6 lists a height range of 100mm–650mm and a length range of 500mm–3000mm. Irregular geometry must also suit the fixture.
The KD-JCX/M-6 fixture is positioned manually. The main inspection instruments perform the tests and generate the report automatically.
The KD-JCX/M-6 high-voltage withstanding range is 0–5000V. This is an equipment range; it does not define the test voltage required for every busbar.
Its grounding test range is 0–25A. The required setting and acceptance criterion must follow the busbar inspection procedure.
The KD-JCX/M-6 table identifies barcode printing and report printing as optional. List the selected output arrangement in the equipment scope.
The published equipment dimensions are L6200mm × W800mm × H800mm. Operating access and service clearances should be considered separately.
KD-JCX/M-6 is listed at 380~415VAC, 50~60Hz and 3kW. Match the site supply to the confirmed electrical configuration.